ADA 101 – Elevator Visible Signal Location
ADAS 2010 407.2.2.2 Elevator Signal Location. Visible signal fixtures shall be centered at 72 inches minimum above the finish floor or ground. The visible signal …
ADAS 2010 407.2.2.2 Elevator Signal Location. Visible signal fixtures shall be centered at 72 inches minimum above the finish floor or ground. The visible signal …
ADAS 2010 503.3 Passenger Loading Zones Access Aisle Passenger loading zones shall provide access aisles complying with 503 adjacent to the vehicle pull-up space. Access …
ADAS 2010 407.2.3.1 Elevator Floor Designation Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations …
ADAS 2010 305.5 Position of Clear Floor or Ground Space Unless otherwise specified, clear floor or ground space shall be positioned for either forward or …
2010 ADAS 406.6 Diagonal Curb Cuts Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to …
2010 ADAS 404.2.3 Clear Width (Doors) Door openings shall provide a clear width of 32 inches minimum. Clear openings of doorways with swinging doors shall …
2010 ADAS 307.3 Post Mounted Objects Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum …
This has been a good month for ADA accessibility as two municipalities have made progress in bringing their facilities and public right-of-way into compliance with …
2010 ADAS 308.2.1 Forward Reach Unobstructed Where a forward reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward …